Detail GE Sensing Panametrics TransPort PT 878 Ultrasonic Liquid Flowmeter Hub- 081210895144 / 087775599644
Operation and Performance
Fluid Types Acoustically conductive fluids, including most clean liquids, and many liquids with entrained solids or gas bubbles. Maximum void fraction depends on transducer, interrogation carrier frequency, path length and pipe configuration.
Pipe Sizes 0.5 in to 300 in ( 12.7 mm to 7.6 m) and larger
Pipe Wall Thickness Up to 3 in ( 76.2 mm)
Pipe Materials All metals and most plastics. Consult GE for concrete, composite materials, and highly corroded or lined pipes.
Clamp-On Flow Accuracy ( Velocity)
Pipe ID> 6 in ( 150 mm) : ± 1% to 2% of reading typical
Pipe ID< 6 in ( 150 mm) : ± 2% to 5% of reading typical
Accuracy depends on pipe size and whether measurement is one-path or two-path. Accuracy to ± 0.5% of reading may be achievable with process calibration.
Repeatability ± 0.1% to 0.3% of reading
Range ( Bidirectional) – 40 to 40 ft/ s ( – 12.2 to 12.2 m/ s)
Rangeability ( Overall) 400: 1
Specifications assume a fully developed flow profile ( typically 10 diameters upstream and 5 diameters downstream of straight pipe run) and flow velocity greater than 1 ft/ s ( 0.3 m/ s) .
Measurement Parameters Volumetric flow, totalized flow and flow velocity
Electronics
Flow Measurement Patented Correlation Transit-Time mode
Enclosure Submersible IP67
Dimensions Weight 3 lb ( 1.36 kg) ,
Size ( h x w x d) 9.4 in x 5.5 in x 1.5 in
( 238 mm x 138 mm x 38 mm)
Display 240 x 200 pixel backlit LCD graphic display
Keypad 25-key rubberized tactile membrane keypad
Internal Battery Rechargeable battery: 9 to 11 hr of continuous operation
Battery Charger Input 100 to 250 VAC, 50/ 60 Hz, 0.38 A
Memory FLASH memory, field-upgradable
Operating Temperature – 4° F to 131° F ( – 20° C to 55° C)
Storage Temperature – 40° F to 158° F ( – 40° C to 70° C)
To ensure maximum battery life, storage temperature exceeding 35° C ( 95° F) is not recommended for more than one month.
Standard Inputs/ Outputs
One 0/ 4 to 20 mA current output, 550 O maximum load
One user-selectable pulse ( solid state, 5 V maximum) or frequency ( 5 V square wave, 100 to 10, 000 Hz)
Two 4 to 20 mA analog inputs with switchable power supply for loop-powered temperature transmitters
Digital Interface Infrared communication port for printer or PC interface
Site-Parameter Programming
Menu-driven operator interface using keypad and " soft" function keys
Online help functions including pipe tables
Storage for saving site parameters
Data Logging
Memory capacity to log over 100, 000 flow data points
Keypad programmable for log units, update times, and start and stop time
Display Functions
Graphic display shows flow in numerical or graphic format
Displays logged data
Extensive diagnostic parameters
Supports multiple languages: Dutch, English, French, German, Italian, Japanese, Portuguese, Russian, Spanish, Swedish and others
European Compliance Battery-powered system complies with EMC Directive 89/ 336/ EEC and transducers comply with PED 97/ 23/ EC for DN< 25
Clamp-On Ultrasonic Flow Transducers
Temperature Ranges
Standard: -40° F to 302° F ( -40° C to 150° C)
Optional: -328° F to 752° F ( -200° C to 400° C)
See specific transducer for exact temperature range.
Mountings Stainless steel chain or strap, welded or magnetic clamping fixtures
Area Classifications
Standard: General purpose
Optional: Weatherproof Type 4X/ IP66
Optional: Submersible IP67/ 68
PT878 electronics are designed for general purpose areas.
Transducer Cables
Standard: One pair of LEMO® coaxial transducer connectors with 25-ft ( 8-m) cables
Optional: 1, 000-ft ( 305-m) extension cables available for most transducers
Thickness-Gauge Option
Transducer Dual-element transducer
Pipe-Thickness Range 0.05 in to 3 in ( 1.3 mm to 76.2 mm)
Pipe Materials Most standard metal and plastic pipe materials
Accuracy ± 1% typical or ± 0.002 in ( ± 0.05 mm)
Thermal Exposure Continuous operation to 100° F ( 37° C) ;
intermittent operation to 500° F ( 260° C) for 10 sec followed by 2 min air cooling
Additional Options
PC-Interface Software The TransPort PT878 communicates with a PC through the infrared interface and Windows® operating systems. Consult the manual for details on sites, logs and other operations with a PC.
Printer
Infrared, portable, thermal printer with rechargeable battery and 120 to 240 VAC power supply/ recharger
Weight 13 oz ( 370 g) , size 6.3 in x 6.5 in x 2.3 in ( 160 mm x 164.2 mm x 59 mm) , print width 4 in ( 104 mm)
RS232-to-Infrared Infrared adapter plugs into any available serial port to give desktop PCs infrared capability.
Tampilkan Lebih Banyak